ort columns for the core, fuel channels, thermal shields, baffles, core grid plates and diffuser plates.
9. Heat exchangers:
Heat exchangers (steam generators) especially designed or prepared for use in the primary coolant circuit of a nuclear reactor as defined in paragraph 1 above.
10. Neutron detection and measuring instruments:
Especially designed or prepared neutron detection and measuring instruments for determining neutron flux levels within the core of a nuclear reactor as defined in paragraph 1 above.
11. Plants for the fabrication of nuclear reactor fuel elements, and equipment especially designed or prepared therefor.
12. Plants for the conversion of uranium and plutonium for use in the fabrication of fuel elements and the separation of uranium isotopes, and equipment especially designed or prepared therefor.
Annex B
LIST
OF FACILITIES IN THE RUSSIAN FEDERATION
Part A
Facilities selected by the International Atomic Energy
Agency for the application of safeguards provided for in
the Safeguards Agreement for the Russian Federation
1. Facilities where nuclear material, material and equipment transferred to the Russian Federation pursuant to this Agreement, equipment based on technology and nuclear material recovered or produced as a by-product are to be located are as follows:
NIL
2. Facilities where technology transferred to the Russian Federation pursuant to this Agreement is to be used are as follows:
NIL
Part B
Facilities eligible, but not selected by the International
Atomic Energy Agency, for the application of safeguards
provided for in the Safeguards Agreement
for the Russian Federation
1. Facilities where nuclear material, material and equipment transferred to the Russian Federation pursuant to this Agreement, equipment based on technology and nuclear material recovered or produced as a by-product are to be located are as follows:
Angarsk International Uranium Enrichment Center
2. Facilities where technology transferred to the Russian Federation pursuant to this Agreement is to be used are as follows:
NIL
Annex C
LEVELS OF PHYSICAL PROTECTION
Category III
(as defined in the attached table)
Use and storage within an area to which access is controlled.
Transportation under special precautions including prior arrangements among sender, recipient and carrier, and prior agreement between entities subject to the jurisdiction and regulation of supplier and recipient States, respectively, in case of international transport, specifying time, place and procedures for transferring transport responsibility.
Category II
(as defined in the attached table)
Use and storage within a protected area to which the access is controlled, i.e., an area under constant surveillance by guards or electronic devices, surrounded by a physical barrier with a limited number of points of entry under appropriate control, or any area with an equivalent level of physical protection.
Transportation under special precautions including prior arrangements among sender, recipient and carrier, and prior agreement between entities subject to the jurisdiction and regulation of supplier and recipient States, respectively, in case of international transport, specifying time, place and procedures for transferring transport responsibility.
Category I
(as defined in the attached table)
Nuclear material in this catego
> 1 2 3 ... 16 17 18 19